Ammonia Sensitive Sensor
- Monitoring ammonia leakage in refrigerating plants
- Applicable for a medium temperature of at least -8 °C
- Special PTFE membrane
- Easy replacement of membrane
Ammonia Transmitter or Controller
- Plain language operation, multilingual
- Graphic display with backlight
- Easy to install plug-type terminal strips
- Electrode monitoring
Ammonia Accessories
- Installation of probes 120 x 12 mm possible
- For 1 and 3 probes with Pg13.5 connection
- Favorable chemical compatibility
- Perfect probe protection
- Various process connections
Chlorine Dioxide Measuring Cells
- Two-electrode principle
- Easy calibration
- Integrated temperature compensation
- Proven measuring system
- Analog and digital version
Chlorine Dioxide Transmitter or Controller
- Up to four analysis inputs in any combination for direct connection of sensors for liquid analysis
- Up to 21 further measuring signals can be connected either directly or via interface
- Interfaces: USB host, USB device, Modbus, PROFIBUS DP, Ethernet
- Ethernet function: web server, alarm alerts by email, setup per PC, readout of recorded measurement data
- Vibrant TFT color graphics screen with 5.5" diagonal screen sizes, 320 × 240 pixels, and 256 colors
- Intuitive operation via touchscreen
- Wall-mounted housing (protection type IP67) with spacious connection area
Chlorine Dioxide Accessories
- Installation of probes 120 x 12 mm possible
- For 1 and 3 probes with Pg13.5 connection
- Favorable chemical compatibility
- Perfect probe protection
- Various process connections
Total Chlorine Measuring Cells
- Three-electrode principle
- Easy calibration
- Integrated temperature compensation
- Proven measuring system
- Analog and digital version
Total Chlorine Transmitter or Controller
- Up to four analysis inputs in any combination for direct connection of sensors for liquid analysis
- Up to 21 further measuring signals can be connected either directly or via interface
- Interfaces: USB host, USB device, Modbus, PROFIBUS DP, Ethernet
- Ethernet function: web server, alarm alerts by email, setup per PC, readout of recorded measurement data
- Vibrant TFT color graphics screen with 5.5" diagonal screen sizes, 320 × 240 pixels, and 256 colors
- Intuitive operation via touchscreen
- Wall-mounted housing (protection type IP67) with spacious connection area
Total Chlorine Accessories
- Installation of probes 120 x 12 mm possible
- For 1 and 3 probes with Pg13.5 connection
- Favorable chemical compatibility
- Perfect probe protection
- Various process connections
Free chlorine Measuring Cells
- Two-electrode principle/three-electrode principle
- Easy calibration
- Integrated temperature compensation
- Proven measuring system
- Analog and digital version
Free chlorine Transmitter or Controller
- Plain language operation, multilingual
- Graphic display with background lighting
- Surface-mounted case protection type IP 67
- Calibration routine for chlorine, chlorine dioxide, ozone, hydrogen peroxide, and peracetic acid
- Voltage supply output for 2-wire transmitter according to data sheet 202630
Free chlorine Accessories
- Installation of probes 120 x 12 mm possible
- For 1 and 3 probes with Pg13.5 connection
- Favorable chemical compatibility
- Perfect probe protection
- Various process connections
Conductivity Measuring Cells
- Hygienic sensor design
- Materials are FDA/food-use approved
- Various process connection variants
- A fast-response, internal temperature sensor
- Constructed without seals (parts coming into contact with the medium to be measured)
- Can be combined with JUMO AQUIS 500 Ci and AQUIS touch S/P
Conductivity Transmitter or Controller
- Plain language operation, multilingual
- Graphic display with background lighting
- Can be combined with tecLine Ci, tecLine Ci-S, ecoLine Ci conductivity and temperature sensors
Conductivity Accessories
- For pH and redox electrodes
- For electrodes with integrated temperature probe
- For conductive conductivity measuring cells
PH Measuring Cells
- High-quality measurement sensors
- Great price-performance ratio
- Glass/plastic shaft versions
- Variable insertion lengths
- Fixed cable connection available as an option
PH Transmitter or Controller
- Up to four analysis inputs in any combination for direct connection of sensors for liquid analysis
- Up to 21 further measuring signals can be connected either directly or via interface
- Interfaces: USB host, USB device, Modbus, PROFIBUS DP, Ethernet
- Ethernet function: web server, alarm alerts by email, setup per PC, readout of recorded measurement data
- Vibrant TFT color graphics screen with 5.5" diagonal screen sizes, 320 × 240 pixels, and 256 colors
- Intuitive operation via touchscreen
- Wall-mounted housing (protection type IP67) with spacious connection area
PH Accessories
- Min. and max. value memory
- Hold function
- Adjustable automatic switch-off
- Easy-to-read, 2-line LC display
- Supply from a 9 V block battery
- Display of battery condition
- Compact design
Oxygen Measuring Cells
- Use of indicating device/controller AQUIS 500 RS according to data sheet 202569
- Low operating costs due to reduced maintenance requirements (no electrolyte changes and no polarization voltage)
- Greater calibration intervals due to lower drift behavior
- High measuring accuracy even for low concentrations
- Short response time
- No minimum inflow (no oxygen consumption)
- Secure, digital measured value transmission
Oxygen Transmitter or Controller
- Plain language operation, multilingual
- Graphic display with background lighting
- Calibration routine for dissolved oxygen, chlorine, total chlorine
- Surface-mounted case protection type IP 67
Oxygen Accessories
- Measurement of dissolved oxygen (DO) in aqueous solutions
- Safe 1-point calibration
- 2-wire transmitter (for basic and standard version)
- Electrical isolation of measurement signal (DO) and output signal (mA)
- Easy connection to an existing system (e.g PLC)
- Can be used as stand-alone system in maximum version
- Compensation of temperature, atmospheric pressure and salinity
- Further processing of the temperature of the medium is possible (separate Pt 1000 or 2-wire transmitter)
Turbidity Measuring Cells
- Measuring method based on the 90° scattered light procedure according to DIN EN ISO 7027
- Entire measuring range 0 to 4000 NTU
- Four single measuring ranges (adjustable) as well as automatic measuring range detection
- Secure, digital measured value transmission
- High measuring accuracy, even for low turbidity
- Integrated temperature sensor
- Short response time
- Sensor is precalibrated prior to shipment
- Protection type IP68
- Operating temperature from 0 to 50 °C
- Safe use when the corresponding fittings are used
- Secure measured value display in combination with AQUIS 500 RS, AQUIS touch S and P, and mTRON T
ORP Transmitters
- 2-wire compact and integrated transmitter
- Plug-in graphic display module
- Separated version up to 10 m
- Temperature compensated
- Application oriented probes
- Wide selection of accessories
- Power relay output, programmable
- Explosion-proof models
ORP Controller
- Programmer, indicator and controller for single transmitters and for transmitter groups
- Large, easy to read backlit LCD or OLED display
- Tank visualisation
- Simple 6-key programming
- Datalogger memory: built-in 4 MB Flash memory SD card slot: max. 64 GB
- Transmitter diagnostic capabilities
- Explosion-proof input models
Multiparameter Probe Op 2 mm 3m bare wir
- UV 254 spectral absorption without any reagents or consumables.
- Multi-parameter measurement: SAC254, CODeq, TOCeq & BODeq, Turbidity eq
- Modbus RS-485 digital communication.
- Automatic Turbidity compensation.
Multiparameter Probe Op 50 mm 7m bare wi
- UV 254 spectral absorption without any reagents or consumables.
- Multi-parameter measurement: SAC254, CODeq, TOCeq & BODeq, Turbidity eq
- Modbus RS-485 digital communication.
- Automatic Turbidity compensation
Multiparameter Probe NO3 STAC2 2 ways
- Fingerprint capability: scanning from 190 up to 800nm with unique 1 nm bandwidth
- Versatile sampling: 4 channels and 10 parameters available per channel
- Data connectivity: both local and cloud based data collection by means of a WiFi connection
- Real-time visualization of the water’s fingerprint: BOD / COD / TOC / Nitrates / Pesticides / Aromatic Hydrocarbons
- Secomam UV-Vis technology since 1966!
- Robust and rugged design with high-tech data handling
Total Suspended Solids
- Optical sensor based on absorptiometry
- Range of measure
- SS : 0-50 g/L
- Sludge blanket 0-100 %
- Turbidity 0-4000 FAU
- Digital communication Modbus RS-485
- Strong sensor
Silt Measuring Instrument
- Two probe types, 1.6 and 5.0 mm (ID) tubing
- Easy to clean probe parts
- Exchangeable transmitter and receiver
- Electronics insulated from medium
- Immersible version available
Sludge blanket
- Optical sensor based on absorptiometry
- SS : 0-50 g/L
- Sludge blanket 0-100 %
- Turbidity 0-4000 FAU
- Digital communication Modbus RS-485
- Strong sensor