Temperature Transmitters

Temperature Two-Wire Transmitter

Temperature Two-Wire Transmitter

  • Designs for B head or DIN-rail mounting
  • RTD temperature probes and thermocouples
  • Galvanic isolation
  • Output two-wire 4 to 20 mA, HART® interface
  • Also available with Ex approval
  • Configuration with setup program

Temperature Four-Wire Transmitter

Temperature Four-Wire Transmitter

  • Design width 17.5 or 22.5 mm
  • Mounting on DIN rail, 35 mm
  • Universal measurement input
  • Galvanic isolation
  • Current output, voltage output
  • LCD display
  • Ex and IECEx approval
  • Configuration with setup program

Temperature Two-Wire or Three-Wire Transmitter

Temperature Two-Wire or Three-Wire Transmitter

  • Designs for B head, J head, or DIN-rail mounting
  • Pt100
  • Analog measured value processing
  • Output: two-wire (4 to 20 mA) or three-wire (0 to 10 V)
  • Configuration with setup program

Temperature Four-Wire Transmitter

Temperature Four-Wire Transmitter

  • Design width 22.5 mm
  • Pt100, Pt1000, and potentiometer
  • Adjustable with DIP switches
  • Analog measured value processing
  • Output 0(4) to 20 mA, 0 to 10 V
  • Configuration with setup program

Temperature Programmable Two-Wire Transmitter

Temperature Programmable Two-Wire Transmitter

  • Measuring input for RTD temperature probe, thermocouple, resistor/potentiometer, resistance transmitter, and voltage
  • Input and output are galvanically isolated
  • Control LED (red/green)
  • Configuration directly via USB cable without additional auxiliary voltage
  • Customer-specific linearization
  • Detection of the min./max. process value (drag indicator function including point in time)

Wtrans B - Programmable Head Transmitter with Wireless Data Transmission

Wtrans B - Programmable Head Transmitter with Wireless Data Transmission

  • For stationary and mobile measurements
  • Universal measurement input
  • Radio frequency 868.4 MHz
  • Open air range up to 300 m
  • Configurable transmission interval (1 to 3600 s)

dTRANS T06 – Multifunctional Four-Wire Transmitter

dTRANS T06 – Multifunctional Four-Wire Transmitter

  • High level of galvanic signal isolation
  • Customer-specific linearization
  • Output simulation
  • Min. and max. drag indicator function
  • Operating hours counter
  • Convenient setup configuration (USB powered)

Multifunctional Four-Wire Transmitter in Mounting Rail Case

Multifunctional Four-Wire Transmitter in Mounting Rail Case

  • Universal input for a large number of sensors and standard signals
  • Intuitive operation and configuration on the device or through USB interface with setup program
  • RS485 interface (Modbus RTU) and relay output limit value (option)
  • Intelligent additional functions such as min./max. drag indicator, operating hours counter, and output simulation
  • SIL 2/SIL 3 according to DIN EN 61508 and PL c/d according to DIN ISO 13849 (option)
  • Sensor matching for RTD temperature probes
  • Customer-specific linearization
  • High galvanic signal separation
  • Service and operation hours counter
  • Connection diagram retrievable in the display

Two-Channel Temperature Transmitter with HART®-Ex-SIL

Two-Channel Temperature Transmitter with HART®-Ex-SIL

  • 2 universal measurement inputs (RTD, TC, Ω, mV)
  • High degree of accuracy (0.1 K with Pt100 sensor)
  • Output 4 to 20 mA (single channel, loop powered)
  • 2 enclosure versions (B-head or DIN rail)
  • HART® 7 protocol
  • SIL 2/3 hardware/software according to IEC 61 508
  • Reliable measurement mode through sensor monitoring and device hardware error detection
  • Optional plug-on display for B-head device version

dTRANS T08 – Temperature Transmitter Series 6 mm

dTRANS T08 – Temperature Transmitter Series 6 mm

  • High degree of basic accuracy of up to 0.05 % for all selected temperature measuring ranges
  • Rapid startup, up to 1,000 measuring ranges can be set via DIP switches
  • Response time up to <30 ms
  • High interference immunity according to NAMUR NE21
  • Large ambient temperature range of -25 to +70 °C for precise measurements
  • Low temperature coefficient with errors <0.01 %/°C
  • Close mounting

dTRANS S08 xx – Signal and Isolating Converter Series 6 mm

dTRANS S08 xx – Signal and Isolating Converter Series 6 mm

  • Input and output signal types of the signal converters can be set quickly and simply via DIP switches
  • Basic accuracy for standard signal isolation of up to 0.05 %
  • Fastest conversion of standard signals for control systems (response time up to <7 ms)
  • Safe galvanic signal separation (2500 V AC for all devices)
  • Low power consumption (<0.65 to 1.2 W)
  • Large ambient temperature range of -25 to +70 °C
  • Close-density mounting

Ex-i Repeater Power Supply - Input Isolating Amplifier

Ex-i Repeater Power Supply - Input Isolating Amplifier

  • HART capable
  • SIL2 approval
  • Universal power supply